Platform Features

Everything your hospital needs.
Nothing it doesn't.

A local-first cardiac data gateway that works offline, connects to your HMIS via HL7, and syncs to the cloud for AI and analytics — without ever locking your data away.

Local Gateway

On-premise. Offline-ready. Instant.

A Docker container inside your hospital processes ECG files in seconds with no cloud dependency. Patient data stays on-site unless you choose to sync.

  • Detects new files in under 2 seconds via drop folder watcher
  • Full operation on hospital LAN with zero internet
  • Auto sync queue — records upload when connectivity restores
  • SHA-256 deduplication prevents duplicate records
  • Single Docker container — installs in under 30 minutes
  • SQLite local DB — no separate database server needed
Gateway data flow
ECG DeviceXML · PDF · DICOM
GatewayParse · Match · Store
DashboardAny LAN browser
↕ HTTPS sync when online · HL7 ORU → HMIS at all times
OFFIN CloudAnalytics · AI · Billing

Multi-vendor Parsing

Connects to the devices you already have.

Purpose-built parsers for every major ECG vendor. Drop the file, the gateway handles the rest — no middleware, no drivers, no scripts.

  • GE MAC Series — XML and DICOM
  • Mindray BeneHeart — XML + PDF
  • Philips PageWriter — XML
  • CardioSoft / GE MUSE — XML database export
  • DICOM 12-Lead Waveform Storage (all vendors)
  • Auto vendor detection — no manual config
  • Unsupported files quarantined automatically
GE HealthcareMAC Series · MUSE
XMLDICOM
MindrayBeneHeart series
XMLPDF
PhilipsPageWriter series
XML
CardioSoftGE desktop export
XML
DICOM (all vendors)SOP 1.2.840.10008.5.1.4.1.1.9.1.1
DICOM

ECG Waveform Viewer

Clinical-grade viewer in the browser.

A full 12-lead ECG viewer rendered on HTML Canvas. Standard paper grid, calibration pulse, and colour-coded measurements — no plugins required.

  • Standard 12-lead layout (I, II, III, aVR, aVL, aVF, V1–V6)
  • Configurable speed: 25 mm/s or 50 mm/s
  • Configurable gain: 5, 10, or 20 mm/mV
  • Single-lead strip mode with zoom
  • 1mV calibration pulse on every lead
  • Rhythm strip (Lead II) across full width
  • PNG export for referral attachments
  • Measurements colour-coded: normal / low / high
12-LeadStrip 50 mm/s10 mm/mV
I II III II (Rhythm)
12 leads · 10.0 s · 50 mm/s · 10 mm/mV · 1000 Hz

HL7 & FHIR

Plugs into your existing HMIS.

Send ECG results to Epic, Cerner, DHIMS2, OpenMRS, or any MLLP-compatible system automatically — after every ECG is processed. No manual data entry.

  • HL7 v2 ORU messages via MLLP (port 6661)
  • FHIR R4 API on the cloud platform
  • Configurable HMIS endpoint per gateway
  • Compatible with Epic, Cerner, DHIMS2, OpenMRS
  • HL7 message logging and audit trail
  • Retry on delivery failure
Data routing
Gatewayport 6661
→ HL7 v2 ORU →
↔ FHIR R4 (cloud) ↔
Epic / Cerner
DHIMS2
OpenMRS
Any MLLP system

AI Interpretation

Rule-based now. LLM-ready when you are.

A deterministic rule engine flags clinical abnormalities instantly on all plans. Enterprise unlocks LLM-based interpretation via Claude AI.

  • Heart rate — bradycardia / tachycardia
  • PR interval — short / prolonged detection
  • QRS duration — narrow / wide complex
  • QT/QTc — prolongation risk stratification
  • Axis deviations (P, QRS, T)
  • LLM clinical interpretation (Enterprise)
  • Results returned to gateway automatically
Rule EngineAll plans
Heart rate112 bpm↑ High
PR interval162 msNormal
QRS duration88 msNormal
QTc468 ms↑ Prolonged
QRS axis+42°Normal
LLM / Claude AIEnterprise

"Sinus tachycardia at 112 bpm. QTc prolongation at 468 ms — recommend electrolyte check and medication review. No evidence of acute ST changes. Axis within normal limits."


Security & Compliance

Built for healthcare data from day one.

Every layer designed with patient data protection as a first principle — not an afterthought.

AES-256 at rest

Local SQLite and cloud PostgreSQL encrypted

TLS 1.2+ in transit

All sync traffic encrypted end-to-end

License key per gateway

Hard-fail on expired or invalid keys

Role-based access

Clinician / Technician / Admin roles

Full audit log

Every data access and change recorded

Plan-based retention

30 days to 7 years by tier

HIPAA-Ready Design
AES-256 Encryption
HL7 v2 / FHIR R4
On-premise Option
Audit Logging
Offline-First

Ready to connect your ECG devices?

Start a free trial or talk to our team about your hospital's setup.